Danfoss Pressure Switch

Danfoss pressure switches are electromechanical controls and limiters, that control the pressure of air and liquids within a given pressure range.

All contact systems in Danfoss regulating units incorporate a “snap-action” system that maintains the contact force until the moment of contact break.

This distinguishes them from competing products in which micro switches are used.

Danfoss pressure switch ranges have been produced for industrial applications for more than 50 years and today offers the widest range of any manufacturer. The pressure switch range includes components for general industrial use as well as specialised switches for demanding applications.

Danfoss RT pressure switch is designed to match the majority of land and sea applications – the high performance pressure switch. Danfoss RT-E Switches are designated for industrial refrigeration and general industrial application in explosive zones acc. to 94/9/EC, Atex directive, explosive zone 1, for surface equipment, category 2.

With the Danfoss KPS pressure switch series, special attention has been given to meeting important demands for a high level of enclosure, a robust, compact construction and resistance to shock and vibration.

Danfoss CAS pressure switch are pressure-controlled switches. The position of the contacts depends on the pressure in the inlet connection and the set value. special attention has been given to meeting demands for a high level of enclosure, low differential, robust, compact construction and resistance to shock and vibration.

Danfoss KP / KPI pressure switches are designed for gaseous and liquid media – some types are UL, CSA and FM approved. KP / KPI pressure switches offer a compact, robust design, and proven repeatable performance. Covering a range of pressures from 0.14 to 20 bar and with automatic or manual reset capability, they are produced in Danfoss’ ISO 9001 facilities. The switches are very appealing to customers who want safety, longevity and value, and a welcome offering industrial boiler manufacturers.

Danfoss  MBC 5000 / 5100 pressure switch range – impossible to visually differentiate from the switches in the low pressure ranges – uses a completely new piston to convert the pressure. The pressure conversion by means of a piston forms the basis for the extraordinarily long mechanical lifetime of the switch. Another feature is the extended temperature range, allowing the switch to operate also at lower ambient temperatures.

Characteristics

  • Pressure ranges 16 to 160 bar, 25 to 250 bar, 50 to 400 bar
  • Extraordinary mechanical lifetime (>1 mill. cycles)
  • High reliability
  • High switch point accuracy by repeating cycles
  • Ambient temperatures down to -40°c (-40°F)
  • High stability and vibration-durability
  • Marine approvals such as LR, GL, DNV, BV, ABS, KRS, NKK

The high pressure switch is used in industries where high reliability and long lifetime is of utmost importance i.e. ships and wind turbines.
Typical applications are monitoring of motors, gearboxes, pumps and compressors.

Danfoss CS pressure switches have a three-pole switch and adjustable differential. For automatic start and stop of air compressors and water boosters.

No. Description
DANF-PC-ACB2UA595W-061F7595 ACB-2UA595W 061F-7595 (PACK OF 20)
DANF-PC-ACB2UB10W-061F8053 ACB-2UB10W 061F-8053 (PACK OF 50)
DANF-PC-ACB-2UB418W-118U3720 ACB-2UB418W 118U-3720
DANF-PC-ACB2UB509W-061F7509 ACB-2UB509W 061F-7509 ( PACK OF 20 )
DANF-PC-BCP1-0002 BCP1 017B-0002 (0.1 TO 1.1 BAR) AUTO
DANF-PC-CAS136-3151 CAS136 060-315166 G1/4″ (0 TO 10 BAR)
DANF-PC-CAS145-3161 CAS145 060-316166 (4 TO 40 BAR)
DANF-PC-CS-0225 CS 031E-022566 (IP55/4 TO 12 BAR) G-1/4 FEMALE
DANF-PC-CS-0230 CS 031E-023066 (IP43/4 TO 12 BAR) G-1/2 FEMALE
DANF-PC-CS-0235 CS 031E-023566 (IP55/4 TO 12 BAR) G-1/2 FEMALE
DANF-PC-CS-0255 CS 031E-025566 (IP55/7 TO 20 BAR) G-1/2 FEMALE
DANF-PC-KP15-2008 KP15 060-200891 (AUTO/AUTO)
DANF-PC-KP17B-1268 KP17B 060-126866 (AUTO/MANUAL)
DANF-PC-KP17B-6004 KP17B 060-600466 (PACK OF 36) (AUTO/MANUAL)
DANF-PC-KP17W-1275 KP17W 060-127566 (AUTO/AUTO)
DANF-PC-KP35-1133 KP35 060-113391/060-113491 (PACK OF 48)
DANF-PC-KP35-5047 KP35 060-504766 (-0.2 TO 7.5 BAR)
DANF-PC-KP36-1108 KP36 060-110891 (2 TO 14 BAR)
DANF-PC-KP36-2133 KP36 060-213366
DANF-PC-KP36-2159 KP36 060-215966
DANF-PC-KP36-5387 KP36 060-538766 (2 TO 14 BAR)
DANF-PC-KP36-5391 KP36 060-539166
DANF-PC-KP6B-5191 KP6B 060-519166 (8 TO 42 BAR) MANUAL
DANF-PC-KP6W-5190 KP6W 060-519066/060-602466 (PACK OF 40) AUTO
DANF-PC-KPI35-1217 KPI35 060-121766 (-0.2 TO 8 BAR)
DANF-PC-KPI35-1219 KPI35 060-121966/060-122466 (PACK OF 48)
DANF-PC-KPI36-1189 KPI36 060-118966 (4 TO 12 BAR)
DANF-PC-KPI36-3169 KPI36 060-316966 (2 TO 12 BAR)
DANF-PC-KPI38-5081 KPI38 060-508166 (8 TO 28 BAR)
DANF-PC-KPS31-3109 KPS31 060-3109 (0 TO 2.5 BAR)
DANF-PC-KPS33-3103 KPS33 060-310366 (0 TO 3.5 BAR) G-3/8 MALE (AUTO)
DANF-PC-KPS33-3104 KPS33 060-310466 (0 TO 3.5 BAR) G-1/4 FEMALE
DANF-PC-KPS35-3100 KPS35 060-310066 (0 TO 8 BAR) G-3/8 MALE
DANF-PC-KPS35-3105 KPS35 060-310566 (0 TO 8 BAR) G-1/4 FEMALE
DANF-PC-KPS37-3101 KPS37 060-310166 (6 TO 18 BAR)
DANF-PC-KPS37-3106 KPS37 060-310666 (6 TO 18 BAR)
DANF-PC-KPS39-3102 KPS39 060-310266 (10 TO 35 BAR) G-3/8 MALE
DANF-PC-KPS39-3107 KPS39 060-310766 (10 TO 35 BAR) G-1/4 FEMALE
DANF-PC-KPS39-3192 KPS39 060-319266
DANF-PC-KPS43-3120 KPS43 060-312066 (1 TO 10 BAR)
DANF-PC-KPS45-3121 KPS45 060-312166 (4 TO 40 BAR)
DANF-PC-KPS47-3122 KPS47 060-312266 (6 TO 60 BAR)
DANF-PC-KPU15B-5250 KPU15B 060-5250
DANF-PC-KPU16B-5253 KPU16B 060-5253 (R410A/CO2) (CONV/ CONV)
DANF-PC-MBC5000-0010 MBC 5000 1211-1CB04 061B-001066 (-0.2 TO 4 BAR)
DANF-PC-MBC5100-0001 MBC 5100 3421-1CB04 061B-000166 (5 TO 30 BAR)
DANF-PC-MBC5100-0002 MBC 5100 1411-1DB04 061B-000266 (-0.2 TO 10 BAR)
DANF-PC-MBC5100-0003 MBC 5100 3421-1DB04 061B-000366 (5 TO 30 BAR)
DANF-PC-MBC5100-0004 MBC 5100 1211-1DB04 061B-000466 (-0.2 TO 4 BAR)
DANF-PC-MBC5100-0104 MBC 5100-1211-2DB04 061B-010466 (0.2 TO 4 BAR)
DANF-PC-MBC5100-100066 MBC 5100 3231-1CB04 061B-100066 (5 TO 20 BAR)
DANF-PC-MBC5100-1001 MBC 5100 4241-1CB04 061B-100166 (10 TO 100 BAR)
DANF-PC-MBC5100-1002 MBC 5100 3231-1DB04 061B-100266 (5 TO 20 BAR)
DANF-PC-MBC5100-1003 MBC 5100 4241-1DB04 061B-100366 (10 TO 100 BAR)
DANF-PC-MBC5100-1004 MBC 5100 2431-1DB04 061B-100466 (1 TO 10 BAR)
DANF-PC-MBC5100-1005 MBC 5100 3641-1DB04 061B-100566 (5 TO 40 BAR)
DANF-PC-MBC5100-1007 MBC 5100 3641-1CB04 061B-100766 (5 TO 40 BAR)
DANF-PC-MBC5100-1008 MBC 5100-2431-1CB04 061B-100866 (1 TO 10 BAR)
DANF-PC-MBC5100-1024 MBC 5100-3331-1DB04 061B-102466 (5 TO 25 BAR)
DANF-PC-MBC5100-1052 MBC 5100 3231-0DB04 061B-105266 (5 TO 20 BAR)
DANF-PC-MBC5100-1087 MBC 5100 3231-1DB04 061B-108766 (5 TO 20 BAR)
DANF-PC-MBC5100-1101 MBC 5100 4241-2CB04 061B-110166 (10 TO 100 BAR)
DANF-PC-MBC5100-1104 MBC 5100 2431-2DB04 061B-110466 (1 TO 10 BAR)
DANF-PC-MBC5100-1105 MBC 5100 3641-2DB04 061B-110566 (5 TO 40 BAR)
DANF-PC-MBC5100-5100 MBC 5100 5251-1CB04 061B-510066 (16 TO 160 BAR)
DANF-PC-MBC5100-5101 MBC 5100-5451-1CB04 061B-510166 (25 TO 250 BAR)
DANF-PC-RT110-5291 RT110 017-529166 (0.2 TO 3 BAR)
DANF-PC-RT112-5191 RT112 017-519166 (0.1 TO 1.1 BAR)
DANF-PC-RT113-5196 RT113 017-519666 (0 TO 0.3 BAR)
DANF-PC-RT116-5203 RT116 017-520366 (1 TO 10 BAR)
DANF-PC-RT116E-5201 RT116E 017-520166 (1 TO 10 BAR)
DANF-PC-RT117-5295 RT117 017-529566 (10 TO 30 BAR)
DANF-PC-RT117-5296 RT117 017-529666 (10 TO 30 BAR)
DANF-PC-RT117E-5298 RT117E 017-529866 (10 TO 30 BAR)
DANF-PC-RT121-5215 RT121 017-521566 (-1 TO 0 BAR)
DANF-PC-RT1-5245 RT1 017-524566 (-0.8 TO 5 BAR)
DANF-PC-RT1A-5001 RT1A 017-500166 (-0.8 TO 5 BAR)
DANF-PC-RT1AE-5009 RT1AE 017-500966 (-0.8 TO 5 BAR)
DANF-PC-RT200-5237 RT200 017-523766 (0.2 TO 6 BAR)
DANF-PC-RT262A-0025 RT262A 017D-002566 (0.1 TO 1.5 BAR)
DANF-PC-RT262AE-0030 RT262AE 017D-003066 (0.1 TO 1.5 BAR)
DANF-PC-RT262AL-0043 RT262AL 017D-004366
DANF-PC-RT30AW-5187 RT30AW 017-518766 G1/2A (1 TO 10 BAR)
DANF-PC-RT5-5250 RT5 017-525066 (4 TO 17 BAR) 1/4″ FLARE
DANF-PC-RT5-5255 RT5 017-525566 (4 TO 17 BAR) G-3/8 MALE
DANF-PC-RT5A-5046 RT5A 017-504666 (4 TO 17 BAR) (AMMONIA)
DANF-PC-RT5A-5047 RT5A 017-504766  (AMMONIA)
DANF-PC-RT5A-5052 RT5A 017-505266 (4 TO 17 BAR) (AUTO)
DANF-PC-RT5AL-0040 RT5AL 017L-004066 (4 TO 17 BAR)
DANF-PC-RT6AB-5133 RT6AB 017-513366 (10 TO 28 BAR)
DANF-PC-RT6AEW-5138 RT6AEW 017-513866 (5 TO 25 BAR)
DANF-PC-RT6B-5034 RT6B 017-5034 (10 TO 28 BAR) MANUAL
DANF-PC-RT6S-5075 RT6S 017-507566 (10 TO 28 BAR) (MANUAL)